NOV-IE1500 PV Insulation & Earth Continuity Tester (1500 V)

1500 V insulation tester for PV systems. Measures positive and negative pole-to-earth insulation at the same time, locates ground faults inside a string, and checks protective-earth continuity at 200 mA, with no plant shutdown needed.

Insulation faults are among the most common causes of inverter trips and lost yield in PV plants. The NOV-IE1500 finds them fast. In DUAL mode it measures the insulation resistance of both poles to earth in a single test, with no external shorting switch. GFL mode then pinpoints the faulty module or connector inside the string. RPE mode checks protective-earth continuity at 200 mA, and PI / DAR indices show whether insulation is ageing. Clear OK / NO verdicts make results easy for any technician to interpret.

Key features

1    DUAL mode: positive and negative pole-to-earth insulation in one test

2    Ground-fault locator (GFL): pinpoints the faulty module, cable or junction box in a string

3    Up to 1500 V DC: test voltages of 250 / 500 / 1000 / 1500 V, plus timed testing

4    RPE continuity at 200 mA: with instant OK / NO verdict

5    PI and DAR indices: assess insulation ageing

6    No shutdown needed: tests live strings directly, with no external shorting switch

Specifications

FunctionRangeResolutionAccuracy
DC voltage3 – 1500 V1 V±(1% rdg + 2 V)
AC voltage (TRMS)3 – 1000 V1 V±(1% rdg + 3 V)
Insulation, DUAL mode0.10 – 0.99 MΩ0.01 MΩ±(5% rdg + 5 dgt)
 1.0 – 19.9 MΩ0.1 MΩ±(5% rdg + 5 dgt)
 20 – 100 MΩ1 MΩ±(5% rdg + 5 dgt)
Insulation, TIMER mode0.10 – 9.99 MΩ0.01 MΩ±(5% rdg + 5 dgt)
 10.0 – 100 MΩ0.1 MΩ±(5% rdg + 5 dgt)
Insulation test voltages250 / 500 / 1000 / 1500 V DC  
Continuity (RPE)0.00 – 9.99 Ω0.01 Ω±(2% rdg + 2 dgt)
 10.0 – 100 Ω0.1 Ω±(2% rdg + 2 dgt)
 100 – 1999 Ω1 Ω±(2% rdg + 2 dgt)
RPE test current200 mA  
Additional functionsGFL fault location, PI, DAR, OK / NO verdict  
CertificationCE  

In the box

  • NOV-IE1500 main unit
  • 4 × colour-coded test leads with crocodile clips
  • MC4 adapter connectors (red / black)
  • PC software with USB cable
  • Carry bag with shoulder strap
  • External battery charger
  • Hard carrying case
  • 2 × 20 m extension leads with banana plugs
  • Calibration certificate
  • User manual

Applications

  • IEC 62446-1 commissioning tests on PV strings, combiner boxes and inverters
  • Tracing insulation faults behind inverter isolation alarms
  • Detecting insulation degradation from moisture, dust and damaged cables
  • Insulation testing of cables, transformers and switchgear
  • EV battery packs and high-voltage DC bus monitoring